Diffusion Plug-in Priors for Self-Supervised Ultrasound Video Restoration
Ultrasound videos are limited by hardware-constrained spatial resolution and signal-dependent speckle, while paired low- and high-resolution acquisitions for supervised restoration are rarely…
- 用途
- 原典で確認
- 難易度の目安
- Hard
- 実装コストの目安
- High
概要
Ultrasound videos are limited by hardware-constrained spatial resolution and signal-dependent speckle, while paired low- and high-resolution acquisitions for supervised restoration are rarely available. We aim to jointly super-resolve and despeckle ultrasound videos without paired training data or network retraining. We propose UltraDiff, which uses a frozen pre-trained diffusion model (DM) as a plug-in prior and restores each frame by optimizing the latent seed of the DM sampler under a range-constrained maximum a posteriori formulation. We derive a speckle-aware data-fidelity term from a Rayleigh scale-family model and characterize its relative-residual and variance-adaptive weighting properties. We further introduce a stabilized fidelity that is bounded below and strictly convex in log intensity for positive observations in its unclamped form. A total-variation regularizer complements the DM prior, and a temporal seed update warm-starts each frame from the optimized seed of its predecessor. On EchoNet-LVH videos with simulated speckle and additive noise, UltraDiff with a natural-image prior improves PSNR by 1.24\,dB over the strongest baseline, and ultrasound-related priors improve it further. On real clinical echocardiography videos, UltraDiff reduces the mean absolute error of zero-shot ejection fraction (EF) prediction from 7.31 to 6.37 EF points relative to DUP, the strongest baseline. Combining a speckle-aware fidelity with frozen diffusion priors enables ground-truth-free ultrasound video restoration that benefits downstream measurement. UltraDiff needs neither paired data nor retraining and is not tied to a specific diffusion checkpoint. Code associated with this work will be made publicly available upon acceptance.
参考リンク
リンク先のライセンス・再現性・データ条件をご確認ください。自動分類や実装の目安は保証ではありません。
実装を始めるプロンプト
参考リンクを確認したうえで、次の内容をコピーして利用できます。
# 論文・記事 Diffusion Plug-in Priors for Self-Supervised Ultrasound Video Restoration # 概要 Ultrasound videos are limited by hardware-constrained spatial resolution and signal-dependent speckle, while paired low- and high-resolution acquisitions for supervised restoration are rarely… # 原典 https://arxiv.org/abs/2611.05206 上記の手法を実装してください。実行前に依存関係とライセンスを確認してください。