Uncertainty calibration in Bayesian M/EEG source imaging
M/EEG source imaging requires accurate localization and reliable uncertainty estimates, yet posterior credible regions are rarely assessed for empirical calibration. We present a simulation-based…
- 用途
- 原典で確認
- 難易度の目安
- Hard
- 実装コストの目安
- Low
概要
M/EEG source imaging requires accurate localization and reliable uncertainty estimates, yet posterior credible regions are rarely assessed for empirical calibration. We present a simulation-based framework for uncertainty quantification and calibration of empirical Bayesian inverse methods with closed-form conditional Gaussian posterior summaries. We compare Bayesian minimum norm (BMN) with sLORETA depth weighting and sparse Bayesian learning (SBL) with sparse basis field expansions (S-FLEX). S-FLEX allows retained coefficients to contribute nonzero marginal posterior variance at locations where voxel-wise SBL yields degenerate variances. For BMN, we derive joint source- and noise-variance updates through evidence maximization. We test whether adaptive noise learning yields near-calibrated uncertainties. Both methods retain residual miscalibration, motivating post-hoc isotonic recalibration of credible-region levels using empirical coverage. Simulations assess fixed- and free-orientation models across signal-to-noise ratios (SNR), source sparsity levels, and subject-specific head models, using oracle, baseline-estimated, and adaptively learned noise. Before recalibration, SBL+S-FLEX yields lower Wasserstein localization error, smaller posterior uncertainty, and coverage closer to nominal credibility than BMN+sLORETA. Isotonic recalibration improves both methods, with larger gains for conservative BMN+sLORETA posteriors; transfer across mismatched SNR, sparsity, and head models remains condition dependent. Noise specifications yield broadly consistent reconstruction and uncertainty trends within each estimator. In real auditory MEG data, SBL+S-FLEX provides more focal localization and tighter uncertainties than BMN+sLORETA, suggesting greater statistical power for identifying bilateral auditory sources.
参考リンク
リンク先のライセンス・再現性・データ条件をご確認ください。自動分類や実装の目安は保証ではありません。
実装を始めるプロンプト
参考リンクを確認したうえで、次の内容をコピーして利用できます。
# 論文・記事 Uncertainty calibration in Bayesian M/EEG source imaging # 概要 M/EEG source imaging requires accurate localization and reliable uncertainty estimates, yet posterior credible regions are rarely assessed for empirical calibration. We present a simulation-based… # 原典 https://arxiv.org/abs/2611.06979 上記の手法を実装してください。実行前に依存関係とライセンスを確認してください。