deep-learningarxiv

Uncertainty calibration in Bayesian M/EEG source imaging

M/EEG source imaging requires accurate localization and reliable uncertainty estimates, yet posterior credible regions are rarely assessed for empirical calibration. We present a simulation-based…

Ismail Huseynov / Mohammad Orabe / Srikantan Nagarajan / Stefan Haufe

用途
原典で確認
難易度の目安
Hard
実装コストの目安
Low

概要

M/EEG source imaging requires accurate localization and reliable uncertainty estimates, yet posterior credible regions are rarely assessed for empirical calibration. We present a simulation-based framework for uncertainty quantification and calibration of empirical Bayesian inverse methods with closed-form conditional Gaussian posterior summaries. We compare Bayesian minimum norm (BMN) with sLORETA depth weighting and sparse Bayesian learning (SBL) with sparse basis field expansions (S-FLEX). S-FLEX allows retained coefficients to contribute nonzero marginal posterior variance at locations where voxel-wise SBL yields degenerate variances. For BMN, we derive joint source- and noise-variance updates through evidence maximization. We test whether adaptive noise learning yields near-calibrated uncertainties. Both methods retain residual miscalibration, motivating post-hoc isotonic recalibration of credible-region levels using empirical coverage. Simulations assess fixed- and free-orientation models across signal-to-noise ratios (SNR), source sparsity levels, and subject-specific head models, using oracle, baseline-estimated, and adaptively learned noise. Before recalibration, SBL+S-FLEX yields lower Wasserstein localization error, smaller posterior uncertainty, and coverage closer to nominal credibility than BMN+sLORETA. Isotonic recalibration improves both methods, with larger gains for conservative BMN+sLORETA posteriors; transfer across mismatched SNR, sparsity, and head models remains condition dependent. Noise specifications yield broadly consistent reconstruction and uncertainty trends within each estimator. In real auditory MEG data, SBL+S-FLEX provides more focal localization and tighter uncertainties than BMN+sLORETA, suggesting greater statistical power for identifying bilateral auditory sources.

参考リンク

リンク先のライセンス・再現性・データ条件をご確認ください。自動分類や実装の目安は保証ではありません。

実装を始めるプロンプト

参考リンクを確認したうえで、次の内容をコピーして利用できます。

# 論文・記事
Uncertainty calibration in Bayesian M/EEG source imaging

# 概要
M/EEG source imaging requires accurate localization and reliable uncertainty estimates, yet posterior credible regions are rarely assessed for empirical calibration. We present a simulation-based…

# 原典
https://arxiv.org/abs/2611.06979

上記の手法を実装してください。実行前に依存関係とライセンスを確認してください。

関連する記事