deep-learningarxiv

ReuScope: Auditing Data Reuse and Evaluation Sensitivity in Capsule Vision 2024

We develop ReuScope, a protocol for auditing data reuse and evaluation sensitivity, using Capsule Vision 2024 as a case study. It combines measurements of data relationships with two comparisons:…

Eunseob Choi / Kyeonghun Kim / Hyuk-Jae Lee / Nam-Joon Kim

用途
原典で確認
難易度の目安
Hard
実装コストの目安
High

概要

We develop ReuScope, a protocol for auditing data reuse and evaluation sensitivity, using Capsule Vision 2024 as a case study. It combines measurements of data relationships with two comparisons: changing the evaluation population while holding predictions fixed, and changing training data while holding evaluation fixed. Byte-identical files cross the public training-validation boundary, and all 41 Kvasir-Capsule recordings that contribute frames occur in both partitions. Shared source recordings establish cross-split overlap; missing cross-recording patient identifiers prevent counting unique shared patients. Across ten paired seeds, removing all training rows attributed to Kvasir-Capsule, plus five rows from other sources flagged as near-matches to it, lowers public-validation balanced accuracy from 82.5% to 61.2%. Evaluating the same fitted models on the validation rows of the other sources reverses the comparison: removal improves balanced accuracy by 1.38 percentage points. The public-validation drop measures sensitivity to source removal, not an amount of leakage-induced inflation. Matched controls show that sample size and class counts alone do not explain the observed score differences. An exploratory experiment removes the training neighbors of validation frames that have close training matches, or equally many distant training rows, and yields a difference-in-differences estimate, relative to matched unflagged frames, of -0.355 percentage points in true-class probability; the paired-t interval for accuracy spans zero. The resulting procedure distinguishes observed reuse from conditional performance sensitivity and specifies the population, class support and uncertainty unit for each conclusion.

参考リンク

リンク先のライセンス・再現性・データ条件をご確認ください。自動分類や実装の目安は保証ではありません。

実装を始めるプロンプト

参考リンクを確認したうえで、次の内容をコピーして利用できます。

# 論文・記事
ReuScope: Auditing Data Reuse and Evaluation Sensitivity in Capsule Vision 2024

# 概要
We develop ReuScope, a protocol for auditing data reuse and evaluation sensitivity, using Capsule Vision 2024 as a case study. It combines measurements of data relationships with two comparisons:…

# 原典
https://arxiv.org/abs/2610.41835

上記の手法を実装してください。実行前に依存関係とライセンスを確認してください。

関連する記事