deep-learningarxiv

A Transparent 3-DoF Assistive Device for Upper-Limb Tremor and Ataxia Compensation: Design and Experimental Validation

Assistive devices for patients with neurodegenerative movement disorders must combine high mechanical transparency with the ability to generate corrective interaction forces. Achieving both…

Thomas Dobosz / Veronika Hofmann / Ahmed Barhoma / Ann-Kathrin Henke / Johannes A. Gaus

用途
原典で確認
難易度の目安
Hard
実装コストの目安
Medium

概要

Assistive devices for patients with neurodegenerative movement disorders must combine high mechanical transparency with the ability to generate corrective interaction forces. Achieving both properties simultaneously remains challenging. This paper presents the completed iAssistADL platform, a 3-DoF assistive device for future tremor and ataxia compensation during activities of daily living. The system employs a transparency-oriented mechanical architecture with all actuators located at the base, resulting in low moving mass, decoupled kinematics, and high mechanical transparency. To compensate for friction-induced transparency limitations along the vertical axis, a hybrid control strategy is proposed that combines open-loop force rendering in the horizontal plane with closed-loop force control in the vertical direction. The platform is experimentally evaluated through transparency measurements and static and dynamic force-rendering experiments at representative configurations. Results demonstrate resistive torques below 0.1 Nm in the horizontal plane, end-effector forces of up to approximately 10 N throughout the workspace, and accurate horizontal force rendering up to 4 Hz. While the vertical axis remains limited by friction-induced dynamics at higher frequencies, the proposed system successfully combines high transparency with controlled force generation, establishing a promising hardware platform for future tremor and ataxia compensation.

参考リンク

リンク先のライセンス・再現性・データ条件をご確認ください。自動分類や実装の目安は保証ではありません。

実装を始めるプロンプト

参考リンクを確認したうえで、次の内容をコピーして利用できます。

# 論文・記事
A Transparent 3-DoF Assistive Device for Upper-Limb Tremor and Ataxia Compensation: Design and Experimental Validation

# 概要
Assistive devices for patients with neurodegenerative movement disorders must combine high mechanical transparency with the ability to generate corrective interaction forces. Achieving both…

# 原典
https://arxiv.org/abs/2610.30955

上記の手法を実装してください。実行前に依存関係とライセンスを確認してください。

関連する記事

github実装リンクあり

LLMs-from-scratch — Implement a ChatGPT-like LLM in PyTorch from scratch, step by step

この研究では、COVID-19臨床パスウェイズの予測監視を支援するために、パイプラインを構築しました。このパイプラインには、データリフティング、時間的再構成、イベントログの構築、プリフィックスベースの表現、予測モデルの整合が含まれています。

医療機器へのアクセスを予測する