Memory-Augmented Online Test-Time Adaptation for EEG Motor Imagery via Perturbation Consistency and Confidence Calibration
Recently, electroencephalography (EEG)-based brain--computer interfaces (BCIs) have gained traction as portable neural measurement systems. However, the practical deployment of these instruments is…
- 用途
- 原典で確認
- 難易度の目安
- Hard
- 実装コストの目安
- Medium
概要
Recently, electroencephalography (EEG)-based brain--computer interfaces (BCIs) have gained traction as portable neural measurement systems. However, the practical deployment of these instruments is often hindered by nonstationarity and cross-subject distribution shifts, which lead to significant intersubject inconsistency. Existing adaptation methods remain impractical for real-time measurement scenarios, as they typically require offline access to source or aggregated target data. To address these challenges, this article proposes memory-augmented online test-time adaptation (OTTA) with perturbation consistency and confidence calibration (MOPC), a source-free framework designed to enhance the reliability of BCI instrumentation. MOPC enables the measurement system to update its decoding parameters on the fly during the inference stage, facilitating single-pass adaptation without accessing sensitive source data. We introduce random-mask perturbations to enforce prediction consistency against inherent EEG signal noise and acquisition artifacts. Furthermore, a confidence-calibrated reweighting loss is designed to integrate feature-space similarity, effectively mitigating unreliable pseudolabels and class imbalance during continuous signal acquisition. To ensure system stability and prevent the catastrophic forgetting of established neural patterns, a lightweight memory module is incorporated to regularize parameter updates within a tight latency budget. Evaluated on the BCI IV IIb and OpenBMI datasets, MOPC achieves state-of-the-art performance, outperforming prior methods by 2.22~\% and 3.67~\%, respectively, while keeping the per-trial adaptation latency to approximately 40--60 ms. This study provides a robust, recalibration-free solution for real-time EEG decoding, marking a significant advancement in the precision and usability of practical BCI measurement instruments.
参考リンク
リンク先のライセンス・再現性・データ条件をご確認ください。自動分類や実装の目安は保証ではありません。
実装を始めるプロンプト
参考リンクを確認したうえで、次の内容をコピーして利用できます。
# 論文・記事 Memory-Augmented Online Test-Time Adaptation for EEG Motor Imagery via Perturbation Consistency and Confidence Calibration # 概要 Recently, electroencephalography (EEG)-based brain--computer interfaces (BCIs) have gained traction as portable neural measurement systems. However, the practical deployment of these instruments is… # 原典 https://arxiv.org/abs/2610.30422 上記の手法を実装してください。実行前に依存関係とライセンスを確認してください。